An Industrial AI reference architecture is only useful if it matches the plant you already have. Most plants are organized, on paper and on the network, around ISA-95 and the Purdue model. Security teams review changes in those terms, and so do controls engineers.
This guide maps an Industrial AI reference architecture onto those levels: which components sit where, which protocols carry data between them, where models train and run, and how OT security guidance from NIST SP 800-82 shapes every connection.
An Industrial AI reference architecture is a vendor-neutral template of the components needed to run AI on industrial data, and of how they connect. The core components are connectivity to industrial assets, data normalization and contextualization, a real-time data exchange layer, model inference, model training and central governance. Mapping these components to ISA-95 and the Purdue model ties each one to a network level and a security zone, so engineering, IT and security teams can review the design in terms they already use.
ISA-95 (also published internationally as IEC 62264) is the standard for integrating enterprise and control systems. It defines the information exchanged between business and operations systems, and a standard equipment hierarchy: enterprise, site, area, line and work unit.
The Purdue model groups industrial systems into levels, from the physical process at Level 0 to enterprise IT at Levels 4 and 5, with an industrial demilitarized zone (DMZ) between operations and enterprise networks. Most OT network segmentation is still designed around it.
The two work together. ISA-95 tells you how to name and structure assets and information. The Purdue model tells you where systems sit on the network and which connections are allowed.
Level | Typical systems | Industrial AI role | Protocols and data flow |
|---|---|---|---|
Levels 0–1: Process and basic control | Sensors, actuators, PLCs, drives, robots, CNC machines | Source of signals, states and fault codes. Control logic stays here; AI does not write to it directly | Read by edge connectivity through native PLC protocols, Modbus and OPC UA |
Level 2: Supervisory control | SCADA, HMI, line-level edge nodes | Edge connectivity, normalization and real-time inference for latency-sensitive use cases; alerts to operators | OPC UA client and server; MQTT publishing from the edge |
Level 3: Site operations | MES, historian, site edge servers, site UNS broker | Contextualization with asset models, site Unified Namespace, local storage, site-level models including language models, integration with MES and CMMS | MQTT and Sparkplug B in the UNS; database and API connectors to MES and historian |
Level 3.5: Industrial DMZ | Brokers, replication servers, proxies | Controlled outbound data transfer; staging of model and software packages moving inbound | Outbound-initiated, encrypted connections; no direct inbound paths to Levels 0–2 |
Levels 4–5: Enterprise and cloud | ERP, CMMS, data platforms, cloud ML services | Cross-site analytics, model training and retraining, model registries, enterprise dashboards | Streaming and batch exports; trained models flow back down to Levels 2–3 for inference |
The pattern underneath the table is simple: data flows up, models flow down. Signals move up through normalization and context to the systems that train models and compare sites. Trained, versioned models move down through the DMZ to the edge, where they run next to the process.
Aspect | OPC UA | MQTT with Sparkplug B |
|---|---|---|
Pattern | Client/server, with an optional pub/sub mode | Publish/subscribe through a broker |
Best at | Reading structured data, types and metadata from controllers and SCADA | Distributing data from many producers to many consumers |
Typical level | Levels 1–2 | Level 3 and above |
Role in Industrial AI | Getting accurate, browsable data out of devices | Sharing contextualized data once with every model, dashboard and application that needs it |
A practical rule: OPC UA and native protocols in, MQTT out. The edge layer reads each device in the protocol it speaks, normalizes and contextualizes the data, then publishes it once to a Unified Namespace built on an MQTT broker. Sparkplug B adds a defined payload format and state awareness, so consumers know when a device or edge node goes offline.
Level 2 (line edge): use cases that need responses in milliseconds to seconds, such as vision inspection and anomaly detection on high-frequency signals.
Level 3 (site): site-wide models, correlation across lines, and language models that answer questions over site data.
Levels 4–5 (enterprise and cloud): model training and retraining, fleet benchmarks and cross-site analytics.
Models trained centrally are packaged, versioned and promoted down through the DMZ to the edge nodes that run them. Central management tracks which version runs where and rolls a site back if a version underperforms.
NIST Special Publication 800-82 Revision 3, Guide to Operational Technology (OT) Security, is the reference many security teams use for OT environments. These principles apply directly to Industrial AI components:
Segment by level and function. Place each Industrial AI component in the zone that matches its function. Edge connectivity belongs near the equipment it reads; training platforms belong in the enterprise zone. ISA/IEC 62443 zones and conduits are a common way to formalize this.
Prefer outbound-initiated connections. Data should leave OT through connections the OT side opens. Avoid inbound paths from enterprise networks or the internet to Levels 0–2.
Apply least privilege. Give AI components read-only access to control data by default. Any write access needs separate approval, a narrow scope and logging.
Authenticate and encrypt. Use certificates and TLS for OPC UA and MQTT, and per-topic publish and subscribe permissions in the UNS.
Monitor and log. Record which users, applications and models accessed which data, and which model version is deployed where.
Design for degraded operation. If an edge node, the network or a model fails, the process must keep running safely, and the AI component must fail visibly.
Litmus Edge is part of Databricks' Industrial AI Reference Architecture for Manufacturing, and that design follows the same up-and-down pattern:
- 1.
Litmus Edge collects, normalizes and contextualizes OT data at the site, connecting to more than 250 industrial protocols across PLCs, CNC machines, SCADA, MES and historians.
- 2.
Real-time data streams from Litmus Edge into Databricks through Kafka, and historical datasets are uploaded in batch for analysis and model training.
- 3.
In Databricks, data moves through a bronze, silver and gold medallion structure to become analytics-ready.
- 4.
Models trained in Databricks are deployed back to Litmus Edge for real-time inference and automation on the shop floor.
Level | Litmus component | What it does there |
|---|---|---|
Levels 1–2 | Litmus Edge (Data Connectivity) | Native connectors, Device Discovery and Tag Discovery |
Levels 2–3 | Litmus Edge (DataOps, Edge Analytics, Edge AI) | Normalization, contextualization, data models, local storage and edge inference |
Level 3 | Litmus UNS | Governed Unified Namespace on an enterprise-grade MQTT broker, with an ISA-95-aligned hierarchy and topic-level access control |
Site or enterprise data center | Litmus Edge Manager | Central deployment, monitoring, and data model and AI model management across sites |
Enterprise | Litmus Data Catalog | Metadata discovery, lineage and governance across OT and IT |
Levels 4–5 | Litmus Edge (Data Integration) | Managed connectors to cloud platforms, data platforms and message brokers |
Explore the full design in the Industrial AI architecture hub.
What is the reference architecture for Industrial AI?
It is a template of the components needed to run AI on industrial data: connectivity, data contextualization, a real-time data exchange layer, inference, training and governance. Mapping it to ISA-95 and the Purdue model shows where each component sits on the network and which connections are allowed.
How does ISA-95 relate to the Purdue model?
ISA-95 defines how enterprise and control systems exchange information and how equipment is organized in a hierarchy. The Purdue model defines network levels for segmentation. Industrial AI designs use ISA-95 for naming and structure, and the Purdue model for placement and security.
Should Industrial AI use OPC UA or MQTT?
Both, for different jobs. OPC UA and native protocols read data from controllers and SCADA at Levels 1–2. MQTT, often with Sparkplug B, distributes contextualized data to many consumers at Level 3 and above.
Where should AI models run in the Purdue model?
Latency-sensitive inference runs at Level 2 or 3, close to the process. Training, retraining and cross-site analysis run at Levels 4–5. Trained models move down through the DMZ to the edge.
Does NIST SP 800-82 apply to Industrial AI?
Yes. Industrial AI components connect to OT systems, so the same principles apply: segmentation, outbound-initiated connections, least privilege, encryption, monitoring and safe degraded operation.
A reference architecture becomes useful once it is mapped to your own levels, zones and systems. Book a demo to walk through how Litmus fits your Purdue levels, or explore the Litmus integration with Databricks.